Sustainability, Vol. 16, Pages 11212: Evaluation of a Grid-Connected Photovoltaic System at the University of Brasília Based on Brazilian Standard for Performance Monitoring and Analysis
Sustainability doi: 10.3390/su162411212
Authors:
Paulo Fernandes
Alex Reis
Loana N. Velasco
Tânia M. Francisco
Ênio C. Resende
Luiz C. G. Freitas
This work presents the results of research aimed at evaluating the performance of the photovoltaic system connected to the electrical grid at the University of Brasília (UnB), Brazil. Following the guidelines established by the Brazilian Standard for Performance Monitoring and Analysis of Grid-connected Photovoltaic Systems, it was possible to evaluate the system’s performance by determining the Performance Ratio (PR) indicator. The operating temperatures were estimated using measured values of the ambient temperature and solar irradiation. These data were collected by a nearby solarimetric station. Next, the theoretical energy injected into the electrical grid was determined based on calculations of the Direct Current (DC) power at the inverter input and the Alternating Current (AC) power at the inverter output. To this end, the coefficients of the inverter efficiency curve were considered as well as a loss scenario, as recommended. With these results, as well as the information about the total photovoltaics (PV) system AC production obtained from the inverter supervisory system, it was possible to determine the average annual PR achieved and compare the theoretical and practical results obtained. The main contribution of this paper is the performance evaluation of a 125 kWp grid-connected photovoltaic system at the University of Brasília (UnB), assessed using Brazilian Standards for performance monitoring and analysis. The system, installed on the rooftop of the UED building, consists of 298 Canadian Solar HiKu CS3W-420P modules with a 15-degree north pitch angle facing geographic north. It interfaces with the grid through two three-phase inverters, model CSI-75K-T400 (74.76 kWp) and a CSI-50KTL-GI (50.4 kWp). The results showed that the system with a 50kW inverter had an average PR of 78%, while the system with a 75 kW inverter showed a PR variation from 56% to 93%. The information obtained in this work will be used to develop computational tools capable of monitoring and evaluating, in real time, the performance of photovoltaic systems and ensuring that the expected financial return is achieved through the use of preventive and corrective maintenance actions in a timely manner.
Fecha de publicación:
20/12/2024
Fuente: